At any organization, the safety of its employees, customers, and visitors is of the utmost importance. When an emergency arises, it is essential for organizations to have the proper tools in place for quick, efficient evacuation. An emergency push bar is an important tool for providing a fast and secure exit from a building. As such, it is important to review the regulatory standards for the installation of an emergency push bar.
Meeting ADA requirements
Meeting fire codes
Meeting building codes
Meeting UL standards
Meeting ADA requirements
Ensuring that your emergency push bar meets all ADA requirements is a critical step for any business. This is of utmost importance for the health and safety of your customers and employees. The ADA requires that the force needed to activate an emergency push bar must not exceed five pounds of pressure. This requirement applies to the force required to open a door, as well as the force required to activate the release mechanism. Additionally, the emergency push bar must be located at a height between 34 and 48 inches from the floor. These specifications are necessary to meet ADA regulations and should be taken into consideration when designing and installing an emergency push bar.
Meeting fire codes
Meeting fire codes is an essential part of the regulatory standards for an emergency push bar. For an emergency push bar to be compliant with fire safety regulations, it must be certified by a nationally-recognized testing laboratory and approved by the local fire marshal. Additionally, the push bar must be properly tested and maintained according to the manufacturer's instructions, and the fire detection system must be regularly inspected and serviced to ensure proper operation. It is also important to ensure that any combustible materials used in the installation of the push bar are properly fire-rated.
Meeting building codes
Meeting building codes is absolutely critical when it comes to designing an emergency push bar. All emergency push bars must meet the building code requirements of the local jurisdiction in order to be approved for installation. This means that the push bar must be properly labeled and mounted, as well as be of sufficient strength, size, and quality to withstand wear and tear and still be able to activate a door in an emergency. Additionally, all emergency push bars must meet safety requirements set by the National Fire Protection Association or other similar organizations.
Meeting UL standards
Meeting UL standards are essential for any emergency push bar, and the requirements must be met in order to ensure the device is reliable and safe when it is needed. This requires the use of appropriate materials and components, as well as testing to ensure that the bar will operate in the event of an emergency. The bar must also be able to withstand harsh weather conditions, as well as the general wear and tear that comes with everyday use. Additionally, the bar must be able to reset itself after each activation and must be able to be reset from a remote location if necessary. Meeting UL standards is an important step in the installation of any emergency push bar. The suitability of CE EN 1125:2008 for use on fire/smoke resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard.
The correct application of building codes, fire codes, and other regulatory standards must be followed to ensure the proper operation of the push bar. Doorcare hardware tells you more specs.